© 2006 Directed Electronics Vista, CA N919621 11-06Installation GuideIntelliGuard 770

Seite 2

© 2006 directed electronics7h1/10 red (+) 12v constantBefore connecting the RED wire, remove the supplied fuse. Connect to the battery pos-itive termi

Seite 3

www.directed.com8h1/17 orange ground when armedThis wire provides a (-) ground output as long as the system is armed and will ceasewhen the system is

Seite 4

© 2006 directed electronics9h2/3 black/white domelight supervision input (87)This wire determines the output of the BLACK/WHITE H1/15 wire on the main

Seite 5

www.directed.com10ultrasecure immobilizerThe UltraSecure immobilizer circuit in this G5 system is a unique new design thatincorporates the immobilizer

Seite 6

© 2006 directed electronics11type A: positive (+) 12-volt pulseThe system can control Type A door locks directly, with no additional parts. The switch

Seite 7

www.directed.com12type B: negative (-) pulseThis system is common in many Toyotas, Nissans, Hondas, and Saturns, as well asFords with keyless entry sy

Seite 8

© 2006 directed electronics13type C: reversing polarityInterfacing with a reversing polarity system requires either two relays or one 451M(not include

Seite 9

www.directed.com14type D: after-market actuatorsIn order for this system to control one or more after-market actuators, a 451M or tworelays (optional)

Seite 10 - © 2006 directed electronics

© 2006 directed electronics15type E: mercedes-benz and audi (1985 & newer)Type E door locks are controlled by an electrically activated vacuum pum

Seite 11

www.directed.com16type F: one-wire systemType F door locks usually require a negative pulse to unlock and cutting the wire tolock the door. In some ve

Seite 12

Bitwriter™, Code Hopping™, Directed®, Doubleguard®, ESP™, FailSafe®, Ghost Switch™, Learn Routine™, Nite-Lite®, Nuisance Prevention Circuitry®, NPC®,

Seite 13

© 2006 directed electronics17type G: positive (+) multiplexThe door lock switch or door key cylinder may contain either one or two resistors. Wheninte

Seite 14 - IIMMPPOORRTTAANNTT!!

www.directed.com18type H: negative (-) multiplexThe door lock switch or door key cylinder may contain either one or two resistors. Wheninterfacing wit

Seite 15

© 2006 directed electronics19peripheral plug-in harnessessuper bright blue led, 2-pin white plugThe super bright LED operates at (+) 2V DC. Make sure

Seite 16

www.directed.com20blue and orange wires, zone 3 zone 8These wires are multiplex inputs. If a (-) input of less than 0.8 seconds is supplied toeither w

Seite 17

© 2006 directed electronics21arming/disarming diagnosticsThe systems microprocessor monitors and reports all active and violated zones whenarming and

Seite 18

www.directed.com22system status chirpsremote siren silencingWhile the siren is sounding, press the arm/disarm button once to silence the siren butleav

Seite 19

© 2006 directed electronics23system features programmingThis system has many features that can be programmed to accommodate the user'spersonal pr

Seite 20 - Two-Resistor Type

www.directed.com24manual programming instructionsBe sure to document changes by taking note of all feature changes made in program-ming mode.To enter

Seite 21

© 2006 directed electronics25user selectable featuresNNOOTTEE::Factory default settings are shown in bboolldd.* This feature is only available with op

Seite 22

www.directed.com26user selectable features descriptions - column oneadd new remote (only applicable with Radar 2 remote)zAuto-learn new remote control

Seite 23 - NNOOTTEE::

contentswarning! safety first . . . . . . . . . . .1before beginning the installation2after the installation . . . . . . . . .2transmitter functions

Seite 24 - Table of Zones

© 2006 directed electronics27second unlock - off/onzOff: Second unlock output is pulsed at the same time as the unlock output whenthe system is disarm

Seite 25

www.directed.com28panic off/onzOff: The panic feature is not available.zOn: The panic feature is available.auto start setting - off/battery only/temp

Seite 26

© 2006 directed electronics29silent modezThe transmitter channel programmed into this feature will arm/disarm thesystem, but the siren will not chirp.

Seite 27 - Feature Descriptions

www.directed.com30installer selectable featuresTo enter the Installer Selectable Features grid follow the instructions for the UserSelectable Features

Seite 28

© 2006 directed electronics31installer selectable features descriptions - column onelock pulse - single/doublezSingle: One door lock pulse will be out

Seite 29

www.directed.com32installer selectable features descriptions - column twoaccessory output a programmingThe auxiliary accessory output wire (RED/WHITE)

Seite 30

© 2006 directed electronics33accessory output b timer durationzStart Timer: Press the arm/disarm button; the siren will chirp to signal the startof th

Seite 31

www.directed.com34horn output - pulsed/latchedzPulsed: H2/9 YELLOW/WHITE wire will generate a pulsing (-) output when thealarm is in full trigger. Whe

Seite 32

© 2006 directed electronics35zEnter the feature and press the arm/disarm button.zThe lights will flash twice to confirm the engine RPM has been learne

Seite 33

www.directed.com36zPIN Code Confirmation ProcedureBegin this procedure within 15 seconds of finishing the programming sequenceor the new code will not

Seite 34

© 2006 directed electronics1warning! safety firstThe following safety warnings must be observed at all times:zDue to the complexity of this system, in

Seite 35

© 2006 directed electronics37smart power up IIThe Smart Power Up II feature ensures that when the security system is powered backup after being discon

Seite 36

www.directed.com38screw counter-clockwise and retest.auto-immobilization featureImmobilizer circuits automatically activate after 30 seconds.NNOOTTEE:

Seite 37

© 2006 directed electronics39blackjax featureblackjax activation sequenceWhen BlackJax is programmed ON, BlackJax sequence will begin every time the i

Seite 38

www.directed.com40blackjax deactivation sequenceTo deactivate BlackJax turn the key on and then enter the PIN code at any time.bypass blackjax tempora

Seite 39

© 2006 directed electronics41While adjusting this sensor it is required that you strike the vehicle with the amountforce that is desired for the syste

Seite 40

www.directed.com42zHit vehicle at the desired level of impact.zSensor adjusts itself to the force of Hit.zSiren chirps 1 time as confirmation of adjus

Seite 41 - Immobilization

© 2006 directed electronics43zHas the PIN code been changed?The status LED does not work.zMake sure that it is plugged in. (See the Plug-In Harnessess

Seite 42

www.directed.com44wiring reference guideIntelliGuard 770

Seite 43 - Bypass BlackJax temporarily

© 2006 directed electronics45BLACK - GroundBROWN - Speaker Output 1GRAY - (-) Hood Trigger Input Zone 6VIOLET/BLACK - Tach InputGREEN - (-) Door Trigg

Seite 44 - CCAAUUTTIIOONN!!

www.directed.com46BLACK/WHITE - Domelight Supervision Input (87)PINK/BLACK - (-) Accessory Output C (200mA)YELLOW/WHITE - (-) Horn Honk Output (200mA)

Seite 45 - Technology

www.directed.com2OPERATION OF THE REMOTE START MODULE IF THE VEHICLE STARTS INGEAR IS CONTRARY TO ITS INTENDED MODE OF OPERATION. OPERATINGTHE REMOTE

Seite 46 - Plug-In Harnesses

© 2006 directed electronics47

Seite 47

www.directed.com48notes_______________________________________________________________________________________________________________________________

Seite 48

© 2006 directed electronics3transmitter functionsThis system uses computer-based code learning to learn the transmitter buttons. Thismakes it possible

Seite 49

www.directed.com4Button three times, then ButtonThese buttons adjust the optional dual-zone radar sensor.Button three times, then ButtonThese button

Seite 50

© 2006 directed electronics5primary harness wiring guideThis guide describes in detail the connection of each wire. Also included are possible appli-c

Seite 51

www.directed.com6h1/4 violet/black tach inputThis wire monitors engine speed for BlackJax and door locks. Connect it to the nega-tive side of the coil

Kommentare zu diesen Handbüchern

Keine Kommentare