GOSSEN Mueller & Weigert 11
Order Example:
Moving-Coil Ammeter, 72 x 72 mm, −40 ... 0 ... 40 A
Order No.: 3150P BD2 CC40
Front Dim. in mm
48 x 48 72 x 72 96 x 96 144 x 144
Type
DS 48 DS 72 DS 96 DS 144
Order No.
3100P 3150P 3200P 3250P
(in prep.)
Meas. Input − Direct Current Connection Current
Zero Point left direct
−++++
center direct BD2 ++++
1 mA CB1 ++++
5 mA CB5 ++++
10 mA CB10 ++++
20 mA CB20 ++++
1 A/1.5 A/2.5 A/4 A CC1/1.5/2.5/4 ++++
6 A/10 A/15 A CC6/10/15 ++++
25 A CC25 + +++
40 A CC40 −+++
60 A CC60 −+++
10% pos. upper value direct
−0.1 ... 0 ... 1 mA
BD3 CB1 ++++
−2 ... 0 ... 20 mA
BD3 CB20 ++++
mech. suppressed direct
4 ... 20 mA
BD4 −++++
left at shunt resistor .../60 mV Current: ... A BD5 CG ... ++++
Current: ... kA BD5 CH ... ++++
center at shunt resistor .../60 mV Current: ... A BD6 CG ... ++++
Current: ... kA BD6 CH ... ++++
left at shunt resistor .../150 mV Current: ... A BD7 CG ... ++++
Current: ... kA BD7 CH ... ++++
center at shunt resistor .../150 mV Current: ... A BD8 CG ... ++++
Current: ... kA BD8 CH ... ++++
Meas. Input − Direct Voltage Connection Voltage (upper range value)
Zero Point left
−++++
center BD2 ++++
10%
pos. upper value BD3 ++++
direct 10/40/100 V DC10/DC40/DC100 ++++
1 to 300
V (not 10/40/100 V) DC1 to DC300 ++++
400/500/600 V
DC400 to DC600
+
1)
+++
Scale Graduation
corresponds to measuring range
−++++
scale deviates from measuring range
GL ... ++++
without scale
GL95
++++
blank scale, lower and upper value markings, company logo, symbols
GL98 ++++
Scale Characteristics
proportional to current
−++++
per curve
SD999 ... ++++
Applications
standard
−++++
conditionally tropic-proof, climatic category 3
LB4 ++++
Resistance to Vibration /
standard
−++++
Marine Applications
vibration resistance: 2.5 g, shock resistance: 30 g
LN56 ++++
marine applications, German Lloyds
LN8 ++++
Operating Voltage
standard
−++++
600 V (600 V CAT lll)
LS9
+
2)
−
3)
−
3)
−
3)
Bezel
dull black
−++++
dull grey, RAL 7037
MA11 ++++
Glass Faceplate
standard
−++++
anti-glare
MG1 ++++
anti-glare, with red adjustable set pointer
MG98 ++++
Housing and Fasteners
4)
standard
−++++
sheet metal housing with type S screw clamp
ML7
−
++
−
sheet metal housing with type B screw clamp
ML8
−
++
–
polycarbonate housing with 2 leaf springs
ML9 +++
–
polycarbonate housing with Subklew fasteners
ML10 +++
–
Identification none −++++
at rear: ............ MZ998 ... ++++
Scale Inscription none −++++
(Latin lettering)
≤18 characters, 1 line: .......... (not possible for 2
nd
inscription)
SM903 ... +
−−−
≤22 characters, 1 line: ..........
SM902 ...
−
+++
≤37 characters, 2 lines: 1
st
line (15 characters) .., 2
nd
line (22 char.) ..
SM911 ...
−
+++
Additional Numbering none −++++
2
nd
set of numberings, black: ... SK982 ... ++++
2
nd
set of numberings, red (RAL 2002): ... SK983 ... ++++
Red Marker (RAL 2002) none −++++
red marker at: ... ST981 ... ++++
Order Number Instructions:
See page 13 for operating position and degree of protection options.
1) Operating voltage: 600 V (600 V CAT III), only in combination with order no. LS9
2) Not possible for direct connection >6 A.
3) Standard model
4) See page 13 for additional options.
• Select one model each for order numbers with the same sequence of letters.
• No add. entries are required for std. models (identified with bold typeface and “−” in the order no. column).
• An entry with “....” in the order no. column means that order number must be supplemented with text.
➡
➡
+
+
Square Panel Meters
for Direct Current or Direct Voltage
Order Information
Code: B0