Seitenansicht 14
GOSSEN Mueller & Weigert 15
Order Example:
Moving-Iron Ammeter 96 x 96 mm, 100/5 A Transformer Ratio,
2-Fold Overload, Order No 3200E BG18 CG100
Front Dim. in mm
48 x 48 72 x 72 96 x 96 144 x 144
Type DE 48 DE 72 DE 96 DE 144
Order no.
3100E 3150E 3200E 3250E
(in prep.)
Meas. Input Alternating Current Connection Current
rated value 100% direct
−+++
+
2-fold overload direct
BG12 +++
+
1 A/1.5 A/2.5 A/4 A/5 A/6 A
CC1 +++
+
10 A/15 A/25 A/
to
+++
+
40 A/60 A
++
+
100 A
CC100
++
rated value 100% at transformer sec.: 1 A primary current: ... A
BG 13 CG ... +++
+
primary current: ... kA
BG 13 CH ... +++
+
at transformer sec.: 5 A primary current: ... A
BG 14 CG ... +++
+
primary current: ... kA
BG 14 CH ... +++
+
rated value 120% at transformer sec.: 1 A primary current: ... A
BG 15 CG ... +++
+
primary current: ... kA
BG 15 CH ... +++
+
at transformer sec.: 5 A primary current: ... A
BG 16 CG ... +++
+
primary current: ... kA
BG 16 CH ... +++
+
2-fold overload at transformer sec.: 1 A primary current: ... A
BG 17 CG ... +++
+
primary current: ... kA
BG 17 CH ... +++
+
at transformer sec.: 5 A primary current: ... A
BG 18 CG ... +++
+
primary current: ... kA
BG 18 CH ... +++
+
Meas. Input Alternating Voltage Connection Voltage (upper range value)
rated value 100% direct 120 V/150 V/
DC120 +++
+
250 V/300 V/400 V/
to
500 V/600 V
DC600
+
1)
++
+
rated value 120% at transformer sec.: 100 V primary voltage: ... V
BG20 DG ... +++
+
primary voltage: ... kV
BG20 DH ... +++
+
at transformer sec.: 110 V primary voltage: ... V
BG21 DG ... +++
+
primary voltage: ... kV
BG21 DH ... +++
+
Scale Graduation corresponds to measuring range
−+++
+
without scale
GL95
++++
blank scale, lower and upper value markings, company logo, symbols
GL98 +++
+
Applications standard
−+++
+
conditionally tropic-proof, climatic category 3
LB4 +++
+
Resistance To Vibration/ standard
−+++
+
Marine Applications vibration resistance: 2.5 g, shock resistance: 30 g
LN56 +++
+
marine applications, German Lloyds
LN8 ++++
Operating Voltage standard
−++
+
600 V (600 V CAT lll) LS9 +−
2)
2)
2)
Bezel dull black
−+++
+
dull grey, RAL 7037
MA11 +++
+
Glass Faceplate normal
−+++
+
anti-glare
MG1 +++
+
anti-glare, with red adjustable set pointer
MG98 +++
+
Housing and Fasteners standard
−+++
+
sheet metal housing with type S screw clamp
ML7
++
sheet metal housing with type B screw clamp
ML8
++
polycarbonate housing with 2 leaf springs
ML9 +++
polycarbonate housing with Subklew fasteners
ML10 +++
polycarbonate housing with 4 leaf springs
ML11 +++
polycarbonate housing with mounts for H&B Unibloc -grid
ML12 +
3)
3)
4)
polycarbonate housing for manual grid, no fasteners
ML5 +
3)
3)
4)
Identification none
−+++
+
at rear: ............
MZ998 ... +++
+
Scale Inscription none
−+++
+
(Latin lettering) 18 characters, 1 line: .......... (not possible for 2
nd
inscription)
SM903 ... +
−−−
22 characters, 1 line: ..........
SM902 ...
++
+
37 characters, 2 lines: 1
st
line (15 char.):.., 2
nd
line (22 char.): ......
SM911 ...
++
+
Additional Numberings none
−+++
+
2
nd
set of numberings, black: ...
SK982 ... +++
+
2
nd
set of numberings, red (RAL 2002): ...
SK983 ... +++
+
Red Marker (RAL 2002) none
−+++
+
red marker at: ...
ST981 ... +++
+
Order Number Instructions:
See page 13 for operating position and degree of protection options.
1) See “Safety Precautions” on page 8 regarding operating and nominal voltages.
2) Standard model
3) Use order number ML9 for H&B Unibloc and manual grids.
4) Standard model is suitable.
Select one model each for order numbers with the same sequence of letters.
No additional entries required for std. models (identified with bold typeface and “” in order no. column).
An entry with “....” in the order no. column means that the order number must be supplemented with text.
+
+
Square Panel Meters
for Alternating Current or Alternating Voltage
Order Information
Code: B0
Seitenansicht 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 75 76