2-3 NUISANCE PREVENTION® CIRCUITRY (NPC®)
ON/
OFF:
NPC®
stops
repeated
triggering
of
the
same
zone.
If
one
zone
is
triggered
three
times
in
one
hour,
that
zone
is
bypassed
for
one
hour,
starting
from
the
time
of
the
third
trigger.
During
that
hour,
if
the
system
detects
a
trigger
on
that
zone
again,
the
system
resets
the
one
hour
timer.
If
one
hour
passes
and
the
zone
has
not
triggered
again,
the
zone
is
activated
and
can
trigger
the
system
again.
NPC®
monitors
sensor
inputs
and
the
door
trigger,
but
does
not
bypass
the
ignition
trigger
at
any
time.
If NPC®
is
turned
off,
the
system
will
respond
to
repeated
triggers
on
the
sensor
inputs
and
will
do
so
indefi-
nitely.
Some
states
have
laws
regulating
how
many
times
a
security
system
can
trigger
before
it
is
considered
a
nuisance
and
the
vehicle
is
towed
away.
2-4 PROGRESSIVE
DOOR
TRIGGERON/OFF:
The
system
responds
to
a
door
trigger
input
with
a
progressive
response.
When
the
door
is
opened
with
the
system
armed,
the
siren
will
chirp
10
times
prior
to
the
full
triggered
sequence.
The
door
trigger
is
still
treated
as
an
instant
trigger
and
closing
the
door
quickly
will
not
prevent
a
full
triggered
sequence
from
occurring.
If
the
progressive
door
trigger
is
programmed
off,
the
full
siren
output
will
occur
the
moment
the
door
is
opened.
2-5VALET PULSE
COUNT
ONE
TO
FIVE
PULSES:
The
system
can
be
programmed
to
count
the
number
presses
of
the
valet
button
before
disarming
the
security
system
or
VRS®.
The
factory
default
setting
is
one
pulse.
The
unit
can
be
set
for
two
to
five
pulses
using
the
two-chirp
setting
to
select
the
pulse
count.
Ghost
Switch
Option:
For
added
security,
the
GRAY
wire
on
the
two-pin
Valet/Program
can
be
connected
to
any
switch
in
the
vehicle
that
provides
a
positive
(+)
momentary
pulse.
2-6
Bypass
Notification ON/OFF:
when
programmed
on,
any
active
zone
input
to
the
system
during
arming
will
generate
a
bypass
notification
chirp.
When
programmed
OFF,
no
bypass
notification
chirps
will
be
generated
if
any
zone
is
active
during
arming.
2-7 Ignition-controlled
DOMELIGHT
SUPERVISION ON/OFF:
If
turned
on,
the
system
will
turn
on
the
domelight
for
30
seconds
when
the
ignition
is
turned
off.
The
optional
domelight
supervision
feature
must
be
installed.
25
©