? Signal lamp flashes red
l Electronics has detected a failure
à Exchange instrument or return it for repair
7.3 Exchanging the el ectronics
In general, all oscillators of series VB60 can be interchanged. If
you want to use an oscillator with a different signal output, you
can download the corresponding operating instructions man-
ual from our homepage under Downloads.
With EExd instruments, the housing cover may only be opened
if there is no explosive atmosphere present.
Proceed as follows:
1 Switch off power supply
2 Unscrew the housing cover
3 Lift the open ing levers of the terminals with a screwdriver
4 Pull the connection cables out of the terminals
5 Loosen the two screws with a Phillips screwdriver (size 1)
2
1
Fig. 12: Loosen the screws
1 Electronics module
2 Screws (2 pcs.)
6 Remove the old oscillator
OPTISWITCH 3100 C - with two-wire output 23
Maintenance and fault rectification
29955-EN-060112
Kommentare zu diesen Handbüchern