Directed Electronics Valet 561T Installationsanleitung Seite 23

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 34
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 22
© 2005 Directed Electronics, Vista, CA—all rights reserved
2233
iinntteerrnnaall pprrooggrraammmmiinngg jjuummppeerr
This jumper is used to determine the light flash output. In the (+) position, the on-board relay is enabled and
the unit will output (+)12V on the H1/11 WHITE wire. In the (-) position, the on-board relay is disabled. The
H1/11 WHITE wire will supply a (-) 200 mA output suitable for driving factory parking light relays. To access the
jumper, open the control module.
NNOOTTEE::
For parking light circuits that draw 10 amps or more, the internal jumper must be switched
to a (-) light flash output. P/N
88661177
or a standard automotive SPDT relay must be used on the
H1/11 light flash output harness wire.
lliigghhtt ffllaasshh jjuummppeerr
NOTE: JUMPER IS
INSIDE THE CASE
Seitenansicht 22