28
©
2005
Directed Electronics, Inc. all rights reserved
Optional Vehicle Recovery System (VRS)
VRS is an optional feature designed to disable a vehicle during a carjacking event. It must be
programmed in the features menu and the Failsafe Starter Kill must be installed for it to work
properly. For operational instructions when testing VRS refer to the owner's manual.
False Alarm Control Technology (FACT)
FACT requires that you change the way you test the system, as FACT will bypass an input zone for
60 minutes. If the system detects the same zone triggering three times AND the triggers are spaced less
than an hour apart, the system will bypass that input zone for 60 minutes. If that zone does not attempt
to trigger the system during the 60-minute bypass period, the zones monitoring will begin again at
the end of the hour. If it does attempt to trigger while bypassed, the 60-minute bypass starts over again.
Disarming and rearming the system does not reset FACT. The only way to reset FACT is for the 60
minutes to pass, without a trigger, or for the ignition to be turned on. This allows the system to be
repeatedly triggered, disarmed and rearmed, while still allowing FACT to bypass a faulty zone.
When disarming the system, 5 chirps indicate FACT is activated. The LED will report the zone that
has been bypassed. (See
Table of Zones
section of this guide.)
Smart Power Up II
The Smart Power Up II feature ensures that when the security system is powered back up after power has
been disconnected, the system will resume the same state it was in before power was lost. For example, if
power is disconnected during a full trigger sequence, the system will still be in the full trigger sequence when
power is reconnected to the unit. If power is disconnected while the unit is disarmed, it will still be disarmed
when power is restored. This also applies to the VRS sequence. If the unit loses power at any time during the
VRS sequence, it will automatically resume the VRS full trigger sequence when the unit is powered back up.