Directed Electronics Matrix 1 Installationsanleitung Seite 7

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 30
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 6
www.clifford.com
7
H1/4 BLACK/WHITE (-) 200 mA domelight supervision output
Connect the H1/4 wire to the optional domelight supervision relay as shown in the following
diagram:
H1/5 GREEN (-) door trigger input
Most vehicles use negative door trigger circuits. Connect the green wire to a wire showing ground
when any door is opened. When connecting to newer model vehicles there is generally a need to use
individual door triggers. See DirectFax document 1076 for wiring instructions. This wire will report
Zone 3.
NOTE: If using a door trigger wire that has a delay, Advanced Menu 2, feature 6 or the 998T
Bitwriter can be used to turn Bypass Notification off.
H1/6 BLUE (-) instant trigger input
This input will respond to a negative input with an instant trigger. It is ideal for hood and trunk pins
and will report on Zone 1. It can also be used with Directed single-stage sensors. The H1/6 blue
instant trigger wire can also be used to shunt sensors during operation of auxiliary channels or remote
start. (See
Bypassing Sensor Inputs
section of this guide.)
IMPORTANT! This output is only intended to drive a relay. It cannot be connected
directly to the domelight circuit, as the output cannot support the current draw of one
or more bulbs.
Seitenansicht 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 29 30

Kommentare zu diesen Handbüchern

Keine Kommentare